Busbar trunking system IP55/65/66

Busbar trunking system  IP55/65/66 Busbar trunking system and busbar distribution system take the largest volume of 0,4kV supply line. Due to many factors busbars' volume in the network is increasing in comparison with cable system. For instance, flat bars with the same cross section as cable of round form are able to pass a high value of current. Busbar is compact and can be used in one phase instead of cables group, busbar also provides an economic efficiency, coefficient of incremental losses of busbar is lower. Busbar is electrical and fire safety in comparison with cable system.
Download pdf files
FE unit is used for electrical power transmission.
Pi unit is used for power transmission and distribution. This unit allows to install tap-off unit into the special doors of the box quickly and without hard mounting works.
FE-S Unıt is used for power transmission.
Circulating unit is used for heat expansion in the straight routes of busbars along more than 200 m.
Horizontal angle joint enables the busbar trunking system to achieve all possible layouts on the horizontal plane. It can be used as vertical unit depends on certain project.
Vertical angle joint enables the busbar trunking system to achieve all possible layouts on the vertical plane. It can be used as horizontal unit depends on certain project.
Horizontal Z-joint is used in case of impossibility of standard horizontal joint application.
Vertical Z-joint is used in case of impossibility of standard vertical joint application. It can be used both horizontal and vertical positions depends on certain project.
Horizontal T-joint is used for taking power from busbar on the horizontal plane. It can be used both horizontal and vertical positions depends on certain project.
Vertical T-joint is used for taking power from busbar on the vertical plane. It can be used both horizontal and vertical positions depends on certain project.
Universal angle joint is used in case of impossibility of standard horizontal and vertical angle-joints application.
Terminal unit is used for insulation and closing the open conducting parts at the end of busbar route.
This unit is used for entrance to the panel and busbar connection to the distribution board bars.
Joint unit with vertical angle is used for entrance to the panel and connection to the distribution board bars in case of impossibility of standard joint units application.
Joint unit with horizontal angle is used for entrance to the panel and connection to the distribution board bars in case of impossibility of standard joint units application.
This unit is used for connnection to dry-type transformer.
This unit is used for supply/taking power from busbar via flexible cable in compliance with references.
Flexible unit is used for busbar route passing through the expansion joint of building with route level differences.
Fire barrier provides busbar passing through the wall and floor structures of different fire zones with thickness 200 mm minimum.
Reducer is used for reducing the busbar discharge capacity with protection in less powerful line parts.
Plug-in box is installed on the tapping-off doors.
Bolt-on box is installed at any mating area of two units.
FE unit is used for electrical power transmission.
Vertical angle joint enables the busbar trunking system to achieve all possible layouts on the vertical plane. It can be used as horizontal unit depends on certain project.
Horizontal angle joint enables the busbar trunking system to achieve all possible layouts on the horizontal plane.
Vertical T-joint is used for taking power from busbar on the vertical plane.
Vertical Z-joint is used in case of impossibility of standard vertical joint application.
Horizontal Z-joint is used in case of impossibility of standard horizontal joint application.
Universal angle joint is used in case of impossibility of standard horizontal and vertical angle-joints application.
Universal angle joint is used in case of impossibility of standard horizontal and vertical angle-joints application.
This unit is used for entrance to the panel and busbar connection to the distribution board bars.
Joint unit with vertical angle is used for entrance to the panel and connection to the distribution board bars in case of impossibility of standard joint units application.
This unit is used for connnection to dry-type transformer.
ADP Joint unit with other busbar types